亚洲无码特级一级片_看国产精品美女黄片_av不卡无码免费播放_国产精品原巨作AV无遮挡

86-15237383444
EXPLAIN

Explanation And Function Of Each Signal Light In The Electronic Control Box Of The PU Projectile Loom Due To Malfunction

Release:hnfzpj Click:13284

PU gripper loom, origin: Switzerland, brand:SULZER. Our company has collected the instructions and functions of various signal lights on the electronic control box of the PU gripper loom for fault diagnosis and maintenance.

1. The flashing blue light indicates a broken warp yarn;

2. The flashing yellow light indicates that the weft yarn is broken or stopped using the stop button;

3. Flashing yellow and red lights means using the emergency stop button to stop the vehicle;

4. When the yellow light is on, it indicates that the fabric has reached the predetermined length;

5. The flashing red light indicates a running fault (reminding the maintenance personnel to repair);

6. When the gripper loom is running, the flashing red light indicates that the PFR module switches to the "OP" position (electronic shuttle failure) or the SFW module switches to the "LS" position (weft detector failure). In addition to the signal light, the LED on the LAL module located in the main control box can also indicate the cause of the machine stop.

Picture of the projectile weaving machine box

The abbreviations next to light-emitting diodes have the following meanings:

MEC=Mechanical Failure

EGS=Electronic control refueling system malfunction

KSA=let-off transmission device * motor failure

MOT=Thermal relay overload of transmission motor

PFR=Early Projectile arrival recognition signal (electronic shuttle detector)

KSV=fuse * overload

WIS=Response of Angle Sensor to Brake Drum Wear and Erosion

VDR=fully twisted leno device * malfunction

KFR=Broken warp yarn on the right-hand side of the loom

KFL=Broken warp yarn on the left-hand side of the loom

AUS=Stop with stop button

NOT=Stop with emergency stop button

SFW=Weft yarn breakage

STZ=Stop the machine after reaching the predetermined fabric length (only effective when the rocker switch is in the "STOP" position)

*Not all looms have it

Pu Projectile weaving machine box

**The accurate shutdown reason is indicated by the PFR module:

FLT=Defective flight trigger

TSN=The sensor at the shuttle receiving device is faulty

KPF=The shuttle does not reach the receiving device or bounces out

PZS=Late  Projectile

PU type electric control box main control board

Instructions for the electric control box, Projectile Loom malfunction, and important instructions for the shuttle signal light:

The rocker switch on the PFR module in the switch box was originally located in the "lower" position. If the switch is set to "OP", the electronic shuttle inspection device will fail. This is indicated by the red signal light flashing when the loom is rotating. The "OP" position is only used for trial running when the loom is free of shuttles.

Imported Loom equipment

The above description of the electronic control box indicates that the Projectile Loom is malfunctioning. The abbreviation for the Projectile Loom signal light is provided for the maintenance personnel of the Projectile Loom to diagnose and repair PU type looms in a timely manner. Welcome everyone to exchange and learn.

FriendLink: BaiDu  Ecer  Xinda Textile  Ec21  Ecplaza  Chinatexnet  Every China  
Copyright © 2016 Xinxiang City Xinda Textile Machinery Parts Co. Ltd 【MANAGE】
ADDRESS:5F West, Unit 53A, Zone A, Huicheng Port Bay, Huixian City, Henan Province,China CONTACT:Mr Yang MOBILE:86-15237383444
TEL:+86-0373-6235050 FAX:+86-0373-6235050 E-MAIL:309816745@qq.com
WEB:http://www.fcbergquistphotos.com
SERVICE
CUSTOMER ONE:
點擊這里
CUSTOMER TWO:
點擊這里
TEL:0373-6235050